An integral part of several International Atomic Energy Agency
sponsored coordinated research programmes involving the sampling and analysis of
ambient airborne particules was the development of a PMlO sampler. Each participant
was provided with such a sampler so that comparable samples would be
obtained by each of the participating groups. Thus, in order to understand the
characteristics of this sampler, we undertoke several characterization studies in
which we examined the aerodynamic collection characteristics of the impactor inlet
and the reproducibility of the sample mass collection. One of the samplers machined
in Belgium was compared with one built from the same design in the U.S.
and comparable results were obtained. The sampler was operated side-by-side with a
commercial PMlO beta gauge and an IMPROVE-design 2.5 ILm cut-point cyclone.
Although the sampler was not wind tunnel tested as required for certification as a
reference sampler, it does provide a collection efficiency that generally follows the
guidelines for a PMlO sampler.