Title of article :
New PM10 inlet design and evaluation
Author/Authors :
Kim، نويسنده , , H.T.; Kim، نويسنده , , Y.J.; Lee، نويسنده , , K.W، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
5
From page :
350
To page :
354
Abstract :
A new PM10 inlet for a beta-gauge sampler was designed based on the particle cup impactor concept. The performance of the inlet was evaluated at near-zero wind velocity in the test chamber and at the wind velocities of 2 and 8 km/hr in the wind tunnel. The performance indicated that particles with aerodynamic diameters of 10 mm or larger were collected in the particle cup and the inlet proved to meet the basic requirement of PM10 sampling
Journal title :
Aerosol Science and Technology
Serial Year :
1998
Journal title :
Aerosol Science and Technology