Title of article :
Optimizing the position of the tube casing slotted section for geothermal wells with a downhole heat exchanger
Author/Authors :
Alberto Carotenuto، نويسنده , , Claudio Casarosa، نويسنده , , Laura Vanoli، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
The use of downhole heat exchangers (DHE) in the exploitation of geothermal resources is
characterized by an absence of mass withdrawal from the aquifer. Although this peculiarity
reduces installation costs it also imposes limits on the heat ¯ow withdrawable (generally less than
100 kW), and, therefore, on the use of DHEs in small applications such as greenhouses, small
buildings or thermal baths. For this reason DHEs are mainly used in super®cial geothermal
aquifers (up to 30mdepth), usually with liquid-phase water at temperatures greater than 60 C. A
study has been made of the in¯uence of the position of the casing slotted section within an
aquifer on the heat withdrawal rates using DHEs. This study numerically simulates an aquifer
using the ®nite-element method to determine the heat ¯ow that can be withdrawn by the DHE
when the slotted section position is varied within a geothermal aquifer. The simulations carried
out also enable us to determine the in¯uence of the main characteristics of the aquifer and the
extraction plant on the design of the tube casing slotted section. On the basis of the numerical
results obtained, a particular con®guration of slotted section is proposed where this is subdivided
into dierent sections, one placed in the lower part of the aquifer and the other in the upper
part. The results obtained have shown that this con®guration optimizes the heat ¯ow drawn
by the DHE from the geothermal aquifer. # 2001 CNR. Published by Elsevier Science Ltd.
All rights reserved.
Keywords :
Geothermal heating , geothermal wells , DHE , Downhole heat exchangers
Journal title :
Geothermics
Journal title :