Title of article
Geothermal reservoir monitoring by continuous self-potential measurements, Mori geothermal field, Japan
Author/Authors
Kasumi Yasukawa، نويسنده , , Tsuneo Ishido، نويسنده , , Iwao Suzuki، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
17
From page
551
To page
567
Abstract
A self-potential (SP) monitoring study was conducted at the Mori geothermal field, Japan, to detect
fluid flow changes in the reservoir caused by well operations. In 2000, eight observation points were
deployed in and around the reservoir region for about 2.5 months, during which the production and
reinjection wells were shut in and then re-opened. Since no reliable remote reference was available,
the SP results were plotted in two ways: adopting an observation point in the target area as reference,
and using the average value of all the observation points as a reference (called the “relative SP”
plot). Although changes in SP corresponding to well operations were detected in both plots, more
reliable results were obtained with the relative SP plot. Based on numerical simulation of SP using
a simplified model of the Mori reservoir, the observed changes are interpreted as being caused by
reservoir pressure changes through electrokinetic coupling.
© 2005 CNR. Published by Elsevier Ltd. All rights reserved.
Keywords
Nigorikawa , Mori , JAPAN , Reservoir monitoring , Self-potential
Journal title
Geothermics
Serial Year
2005
Journal title
Geothermics
Record number
430964
Link To Document