Title of article :
Cell testing by calculated discharge curve method
Author/Authors :
A. B. Djordjevic، نويسنده , , D. M. Karanovic، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
7
From page :
134
To page :
140
Abstract :
The actual discharge curve of a primary or secondary cell is a set of measurements: voltage vs. time, from which the cell/battery characteristics may be determined as well as the family of Calculated Discharge Curves. In addition to the experimental measured discharge curve, the cell relaxation curve is needed. A Calculated Discharge Curve Method (CDCM) was developed to improve discharge curve monitoring and cell characterization. A Calculated Discharge Curve Algorithm (CDCA) was used to generate Calculated Discharge Curves. The Algorithm procedure is presented. Alkaline manganese cell LR 20-VARTA, load 10 Ω, was used for demonstration of the method. The mathematical calculations were conducted on an IBM personal computer using Symphony software
Keywords :
Discharge curve , Galvanic cell , Relaxation curve , Energy balance , Cell overvoltage
Journal title :
Journal of Power Sources
Serial Year :
1999
Journal title :
Journal of Power Sources
Record number :
439985
Link To Document :
بازگشت