A review of standardising SOFC measurement and quality assurance at FZJ
Author/Authors :
V.A.C. Haanappel، نويسنده , , M.J. Smith، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
The need for standardisation/quality assurance (QA) is argued for citing extant problems with consistency, repeatability and reliability of data. A review of the cell testing procedure/QA system used at Forschungszentrum Jülich (FZJ) is given including an outline of how the FZJ system was developed. This is put in the context of more extensive QA systems following the outlines of the ISO 9000 series standards. Examples are used to illustrate how and why a number of standard cell test parameters was adopted. It was found that pre-normative research used to define testing parameters led to an improvement in cell performance generally. Therefore, it is recommended that other solid oxide fuel cells (SOFC) labs develop standardisation in testing and QA systems to maintain and improve their measurement processes.
Keywords :
solid oxide fuel cells , Standardisation and standards , Testing routines , quality assurance