Title of article :
Geometric design improvements for femoral graft-artery junctions mitigating restenosis
Author/Authors :
Z. M. Lei، نويسنده , , C. Kleinstreuer، نويسنده , , J.P. Archie Jr، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Abstract :
The present study is based on the hypothesis that nonuniform hemodynamics, represented by large time-averaged wall shear stress gradients, trigger abnormal biological processes leading to rapid restenosis, i.e. excessive tissue overgrowth and renewed plaque formation, and hence early graft failure. It implies that this problem may be significantly mitigated by finding graft-artery bypass configurations for which the wall shear stress gradient is approximately zero and hence nearly uniform hemodynamics is achieved. These fluid flow and geometric design considerations are applied to four different end-to-side anastomoses for the distal end of a femoral artery bypass with an appropriate test input pulse and a typical 20–80 flow division. A validated finite-volume code has been used to compute the transient three-dimensional velocity vector fields, wall shear stress distributions and surface contours of the wall shear stress gradients. It is shown that large anastomotic flow areas, small continuously changing bifurcation angles, and smooth junction wall curvatures reduce local time-averaged wall shear stress gradients significantly and hence should mitigate restenosis.
Keywords :
Hemodynamics , Shear stress gradient , End-to-side anastomoses , Restenosis.
Journal title :
Journal of Biomechanics
Journal title :
Journal of Biomechanics