Title of article :
Imaging knee position using MRI, RSA/CT and 3D digitisation
Author/Authors :
A McPherson، نويسنده , , J K?rrholm، نويسنده , , V. Pinskerova، نويسنده , , Sosna، B. نويسنده , , S Martelli، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
6
From page :
263
To page :
268
Abstract :
The purpose of this study was to compare 3 methods of imaging knee position. Three fresh cadaver knees were imaged at 6 flexion angles between 0° and 120° by MRI, a combination of RSA and CT and 3D digitisation (in two knees). Virtual models of all 42 positions were created using suitable computer software. Each virtual model was aligned to a newly defined anatomically based Cartesian coordinate system. The angular rotations around the 3 coordinate system axes were calculated directly from the aligned virtual models using rigid body kinematics and found to be equally accurate for the 3 methods. The 3 rotations in each knee could be depicted using anatomy-based diagrams for all 3 methods. We conclude that the 3 methods of data acquisition are equally and adequately accurate in vitro. MRI may be the most useful in vivo.
Keywords :
knee kinematics , Coordinate system , comparative study