Title of article :
Enhanced coronary flow velocity during intra-aortic balloon pumping assessed by transthoracic doppler echocardiography Original Research Article
Author/Authors :
Masaaki Takeuchi، نويسنده , , Yuichi Nohtomi، نويسنده , , Hidetoshi Yoshitani، نويسنده , , Chinami Miyazaki، نويسنده , , Kazuo Sakamoto، نويسنده , , Junichi Yoshikawa، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
9
From page :
368
To page :
376
Abstract :
Objectives The study was done to determine potential utility of measuring coronary flow velocity (CFV) by transthoracic Doppler echocardiography (TTDE) during intra-aortic balloon pumping (IABP). Background Use of IABP has been shown to increase CFV assessed by an invasive technique. The CFV in the left anterior descending coronary artery (LAD) can be measured by TTDE. Methods Coronary flow velocity in the distal LAD by TTDE was measured in 40 critically ill patients requiring IABP. All patients received emergency coronary angiography. Both CFV and pressure data were obtained during 1:2 balloon pumping. Results Adequate diastolic CFV recording was obtained in all patients. The IABP decreased systolic pressure and increased diastolic pressure. Average peak diastolic flow velocity and diastolic velocity time integral was 19 ± 11 cm/s and 7.7 ± 4.4 cm with non-augmented beat. These values were increased significantly (61 ± 38%, 59 ± 35%, p < 0.001) with augmented beat. Significant correlation was noted between % diastolic pressure augmentation and % increase in diastolic CFV (r = 0.62 to 0.69, p < 0.001). There was no significant difference in flow enhancement during IABP, irrespective to the proximal LAD stenosis severity (severe stenosis: 73 ± 70%; intermediate stenosis: 61 ± 29%; no significant stenosis: 58 ± 29%; p = NS, analysis of variance). By continuous recording of CFV, the optimal timing of balloon control could be adjusted to maximize flow velocity during augmentation. Conclusions Use of TTDE can be employed in monitoring CFV augmentation during IABP. The IABP produced significant distal flow enhancement even in patients with critical proximal stenosis. This totally noninvasive approach may help to optimize the benefits of IABP for coronary flow augmentation.
Keywords :
myocardial infarction , blood pressure , LAD , MI , BP , left anterior descending coronary artery , TIMI , Thrombolysis In Myocardial Infarction , QCA , quantitative coronary angiography , APDV , time-averaged peak diastolic velocity , APSV , time-averaged peak systolic velocity , CFV , coronary flow velocity , DFVI , diastolic flow velocity integral , IABP , intra-aortic balloon pumping , SFVI , systolic flow velocity integral , TTDE , transthoracic Doppler echocardiography
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2004
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
458859
Link To Document :
بازگشت