Title of article :
Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: A comparative study with intracoronary ultrasound Original Research Article
Author/Authors :
Alexander W Leber، نويسنده , , Andreas Knez، نويسنده , , Alexander Becker، نويسنده , , Christoph Becker، نويسنده , , Franz von Ziegler، نويسنده , , Konstantin Nikolaou، نويسنده , , Carsten Rist، نويسنده , , Maximilian Reiser، نويسنده , , Carl White، نويسنده , , Gerhard Steinbeck، نويسنده , , Peter Boekstegers، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
7
From page :
1241
To page :
1247
Abstract :
Objectives We evaluated the accuracy of contrast-enhanced multidetector spiral computed tomography (MDCT) for the noninvasive detection and classification of coronary plaques and compared it with intracoronary ultrasound (ICUS). Background Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification and to monitor progression of coronary atherosclerosis. Methods We included 46 consecutive patients with a distinctive risk profile, who were investigated by ICUS (Goldvision, 20 MHz, Jomed Inc., Rancho Cordova, California). Due to the inability to slow the heart rate below 65 beats/min (n = 7) and due to renal insufficiency (n = 2), nine of 46 consecutive patients could not be studied by MDCT (Sensation 16, Siemens, Forchheim, Germany). Results In the remaining 37 patients, 68 vessels were investigated by ICUS, and 58 of these vessels were visualized by MDCT with image quality sufficient for analysis. In these vessels that were divided in 3-mm sections, MDCT correctly classified 62 of 80 (78%) sections containing hypoechoic plaque areas, 87 of 112 (78%) sections containing hyperechoic plaque areas, and 150 of 158 (95%) sections containing calcified plaque tissue. In 484 of 525 (92%) sections, atherosclerotic lesions were correctly excluded. The MDCT-derived density measurements within coronary lesions revealed significantly different values for hypoechoic (49 HU [Hounsfield Units] ± 22), hyperechoic (91 HU ± 22), and calcified plaques (391 HU ± 156, p < 0.02). Conclusions This study demonstrates that, in the case of diagnostic image quality, contrast-enhanced MDCT permits an accurate identification of coronary plaques and that computed tomography density values measured within plaques reflect echogenity and plaque composition.
Keywords :
RCA , LAD , Right coronary artery , left anterior descending artery , MDCT , RCx , Hounsfield units , ICUS , intracoronary ultrasound , HU , multidetector computer tomography , circumflex artery
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2004
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
459005
Link To Document :
بازگشت