Title of article :
Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: A comparison with magnetic resonance imaging Original Research Article
Author/Authors :
Siri Malm، نويسنده , , Sigmund Frigstad، نويسنده , , Einar Sagberg، نويسنده , , Henrik Larsson، نويسنده , , Terje Skjaerpe، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
6
From page :
1030
To page :
1035
Abstract :
Objectives We evaluated the accuracy and reproducibility of contrast echocardiography versus tissue harmonic imaging for measurements of left ventricular (LV) volumes and ejection fraction (EF) compared to magnetic resonance imaging (MRI). Methods Digital echo recordings of apical LV views before and after intravenous contrast were collected from 110 consecutive patients. Magnetic resonance imaging of multiple short-axis LV sections was performed with a 1.5-T scanner. Left ventricular volumes and EF were calculated offline by method of discs. Thirty randomly selected patients were reanalyzed for intraobserver and interobserver variability. Results Compared with baseline, contrast echo increased feasibility for single-plane and biplane volume analysis from 87% to 100% and from 79% to 95%, respectively. The Bland-Altman analysis demonstrated volume underestimation by echo, but much less pronounced with contrast. Limits of agreement between echo and MRI narrowed significantly with contrast: from −18.1% to 8.3% to −7.7% to 4.1% (EF), from −98.2 to −11.7 ml to −59.0 to 10.7 ml (end-diastolic volume), and from −58.8 to 21.8 ml to −38.6 to 23.9 ml (end-systolic volume). Ejection fraction from precontrast echo and MRI differed by ≥10% (EF units) in 23 patients versus 0 after contrast (p < 0.001). At intraobserver and interobserver analysis, limits of agreement for EF narrowed significantly with contrast. Conclusions The two-dimensional echocardiographic evaluation of LV volumes and EF in non-selected cardiac patients was found to be more accurate and reproducible when adding an intravenous contrast agent.
Keywords :
magnetic resonance imaging , MRI , Left ventricle , ejection fraction , ASE , LV , EF , EDV , end-diastolic volume , end-systolic volume , ESV , two-dimensional echocardiography , American Society of Echocardiography , APLAX , apical long-axis , LVO , left ventricular opacification , 2CH , two-chamber , 2D-echo , 4CH , four-chamber
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2004
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
459397
Link To Document :
بازگشت