Title of article :
Detection of retained microbubbles in carotid arteries with real-time low mechanical index imaging in the setting of endothelial dysfunction Original Research Article
Author/Authors :
Jeane M. Tsutsui، نويسنده , , Chun-Feng Xie، نويسنده , , Martin Cano، نويسنده , , James Chomas، نويسنده , , Patrick Phillips، نويسنده , , Stanley J. Radio، نويسنده , , John Lof، نويسنده , , Thomas R. Porter، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
11
From page :
1036
To page :
1046
Abstract :
Objectives We sought to determine if intravenously injected microbubbles would be retained by the carotid arteries (CAs) in the setting of endothelial dysfunction (ED) using a linear transducer equipped with a low mechanical index pulse sequence scheme (PSS). Background Microbubbles normally pass freely through large and small vessels but are retained in regions with ED. New high-frequency low mechanical index PSS can potentially be utilized to image these retained microbubbles. Methods Intravenous albumin- and lipid-encapsulated microbubbles were administered in seven pigs while imaging the CAs before and after a 20% intralipid infusion to induce hypertriglyceridemia. The degree of microbubble retention was quantified by measuring endothelial acoustic intensity (AI) after clearance of free-flowing microbubbles. Microbubble adherence was also evaluated after selective balloon injury of the CAs. The CA diameter responses to acetylcholine were quantified. Results After induction of hypertriglyceridemia, adherence of albumin-encapsulated microbubbles was visually evident in all CAs, and endothelial AI increased significantly (p < 0.001 compared with baseline). The CA responses to acetylcholine went from vasodilation at baseline to vasoconstriction during hypertriglyceridemia. Endothelial AI also increased in the balloon-stretched vessels (p < 0.01 compared with uninjured vessels) after albumin-encapsulated microbubble injection, with a ring of microbubbles selectively adhering to the injured segment. This retention was not observed with lipid-encapsulated microbubbles. Scanning electron microscopy confirmed that albumin-coated microbubbles adhered to endothelial cells. Conclusions Retention of intravenously injected albumin microbubbles occurs in the setting of both global and regional ED in large vessels and can be noninvasively imaged with high-frequency low mechanical index PSS.
Keywords :
AI , endothelial dysfunction , SEM , SCANNING ELECTRON MICROSCOPY , Ca , Carotid artery , Acoustic intensity , ROI , Region of interest , PSS , ED , PESDA , perfluorocarbon-exposed sonicated dextrose albumin , pulse sequence scheme
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2004
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
459398
Link To Document :
بازگشت