Cecilia Fantoni، نويسنده , , Santi Raffa، نويسنده , , Francois Regoli، نويسنده , , Francesco Giraldi، نويسنده , , Maria Teresa La Rovere، نويسنده , , John Prentice، نويسنده , , Francesca Pastori، نويسنده , , Simona Fratini، نويسنده , , Jorge A. Salerno-Uriarte، نويسنده , , Helmut U. Klein، نويسنده , , Angelo Auricchio، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
Objectives
This study sought to report long-term changes of cardiac autonomic control by continuous, device-based monitoring of the standard deviation of the averages of intrinsic intervals in the 288 five-min segments of a day (SDANN) and of heart rate (HR) profile in heart failure (HF) patients treated with cardiac resynchronization therapy (CRT).
Background
Data on long-term changes of time-domain parameters of heart rate variability (HRV) and of HR in highly symptomatic HF patients treated with CRT are lacking.
Methods
Stored data were retrieved for 113 HF patients (New York Heart Association functional class III to IV, left ventricular ejection fraction ≤35%, QRS >120 ms) receiving a CRT device capable of continuous assessment of HRV and HR profile.
Results
The CRT induced a reduction of minimum HR (from 63 ± 9 beats/min to 58 ± 7 beats/min, p < 0.001) and mean HR (from 76 ± 10 beats/min to 72 ± 8 beats/min, p < 0.01) and an increase of SDANN (from 69 ± 23 ms to 93 ± 27 ms, p < 0.001) at three-month follow-up, which were consistent with improvement of functional capacity and structural changes. Different kinetics were observed among these parameters. The SDANN reached the plateau before minimum HR, and mean HR was the slowest parameter to change. Suboptimal left ventricular lead position was associated with no significant functional and structural improvement as well as no change or even worsening of HRV. The two-year event-free survival rate was significantly lower (62% vs. 94%, p < 0.005) in patients without any SDANN change (Δ change ≤0%) compared with patients who showed an increase in SDANN (Δ change >0%) four weeks after CRT initiation.
Conclusions
Cardiac resynchronization therapy is able to significantly modify the sympathetic-parasympathetic interaction to the heart, as defined by HR profile and HRV. Lack of HRV improvement four weeks after CRT identifies patients at higher risk for major cardiovascular events.
Keywords :
CRT , heart rate , Heart rate variability , heart failure , Hf , HRV , HR , cardiac resynchronization therapy , SDNN , SDANN , CRT-D , cardiac resynchronization therapy device with defibrillator back-up , standard deviation of the averages of intrinsic intervals in the 288 five-min segments of a day , standard deviation of RR intervals