Title of article :
Treatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve: Mid-Term Follow-Up From the Initial Feasibility Studies: The French Experience Original Research Article
Author/Authors :
Alain Cribier، نويسنده , , Hélène Eltchaninoff، نويسنده , , Christophe Tron، نويسنده , , Fabrice Bauer، نويسنده , , Carla Agatiello، نويسنده , , Deborah Nercolini، نويسنده , , Sydney Tapiero، نويسنده , , Pierre-Yves Litzler، نويسنده , , Jean-Paul Bessou، نويسنده , , Vasilis Babaliaros، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
10
From page :
1214
To page :
1223
Abstract :
Objectives The aim of this work was to study the feasibility, safety, efficacy, and durability of percutaneous heart valve (PHV) implantation in the aortic position. Background We developed a PHV (equine pericardium valve in a balloon-expandable, stainless-steel stent) to treat patients with inoperable aortic stenosis (AS). Methods Thirty-six patients (aortic valve area ≤0.7 cm2, New York Heart Association [NYHA] functional class IV, and severe comorbidities), formally declined for surgery, were recruited on a compassionate basis. The PHV was implanted by retrograde or antegrade trans-septal approach. Clinical and echocardiographic outcomes were assessed serially. Results Twenty-seven patients were implanted successfully (23 antegrade, 4 retrograde) in the subcoronary position with improvement in valve area (0.60 ± 0.11 cm2 to 1.70 ± 0.10 cm2, p < 0.0001) and transvalvular gradient (37 ± 13 mm Hg to 9 ± 2 mm Hg, p < 0.0001). Paravalvular aortic regurgitation was grade 0 to 1 (n = 10), grade 2 (n = 12), and grade 3 (n = 5). One week post-procedure, improvement in left ventricular function (45 ± 18% to 53 ± 14%, p = 0.02) was most pronounced in patients with ejection fraction <50% (35 ± 10% to 50 ± 16%, p < 0.0001). Thirty-day major adverse events after successful implantation were 26% (pericardial tamponade, stroke, arrhythmia, urosepsis, and one death unexplained at autopsy). Eleven patients are currently alive with follow-up of 9 months (n = 2), 10 months (n = 3), 11 months (n = 1), 12 months (n = 2), 23 months (n = 1), and 26 months (n = 2). All patients experienced amelioration of symptoms (>90% NYHA functional class I to II). Percutaneous heart valve function remained unchanged during follow-up, and no deaths were device-related. Conclusions Percutaneous heart valve implantation is feasible in inoperable patients with end-stage AS leading to hemodynamic and clinical improvement. Continued advances and improved patient selection should decrease adverse events in the near future.
Keywords :
myocardial infarction , PHV , AVA , MI , NYHA , New York Heart Association , TTE , aortic valve area , BAV , percutaneous heart valve , transthoracic echocardiography , MACCE , major adverse cardiac and cerebrovascular events , balloon aortic valvuloplasty , I-REVIVE , Initial Registry of EndoVascular Implantation of Valves in Europe trial , RECAST , Registry of Endovascular Critical Aortic Stenosis Treatment trial
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2006
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
460646
Link To Document :
بازگشت