Title of article :
Deep dermal burn due to contact with stomach contents
Author/Authors :
R. Alvi، نويسنده , , P. Walmsley، نويسنده , , M. I. James، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
A patient sustained deep dermal burns from contact with gastric contents following disconnection of his percutaneous endoscopic gastrostomy (PEG) tube. We discuss the complications of gastrostomies and add this as a rare complication, which may be prevented by a modification to the outlet control of a PEG tube.
Keywords :
Chemical burns , Percutaneous endoscopic gastrostomy tube