Title of article :
Multidetector Computed Tomography Myocardial Perfusion Imaging During Adenosine Stress Original Research Article
Author/Authors :
Richard T. George، نويسنده , , Caterina Silva، نويسنده , , Marco A.S. Cordeiro، نويسنده , , Anthony DiPaula، نويسنده , , Douglas R. Thompson، نويسنده , , William F. McCarthy، نويسنده , , Takashi Ichihara، نويسنده , , Joao A.C. Lima، نويسنده , , Albert C. Lardo، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
8
From page :
153
To page :
160
Abstract :
Objectives The purpose of this study is to validate the accuracy of multidetector computed tomography (MDCT) to measure differences in regional myocardial perfusion during adenosine stress in a canine model of left anterior descending (LAD) artery stenosis, during first-pass, contrast-enhanced helical MDCT. Background Myocardial perfusion imaging by MDCT may have significant implications in the diagnosis and treatment of coronary artery disease. Methods Eight dogs were prepared with a LAD stenosis, and contrast-enhanced MDCT imaging was performed 5 min into adenosine infusion (0.14 to 0.21 mg/kg/min). Images were analyzed using a semiautomated approach to define the regional signal density (SD) ratio (myocardial SD/left ventricular blood pool SD) in stenosed and remote territories, and then compared with microsphere myocardial blood flow (MBF) measurements. Results Mean MBF in stenosed versus remote territories was 1.37 ± 0.46 ml/g/min and 1.29 ± 0.48 ml/g/min at baseline (p = NS) and 2.54 ± 0.93 ml/g/min and 8.94 ± 5.74 ml/g/min during adenosine infusion, respectively (p < 0.05). Myocardial SD was 92.3 ± 39.5 HU in stenosed versus 180.4 ± 41.9 HU in remote territories (p < 0.001). There was a significant linear association of the SD ratio with MBF in the stenosed territory (R = 0.98, p = 0.001) and between regional myocardial SD ratio and MBF <8 ml/g/min, slope = 0.035, SE = 0.007, p < 0.0001. Overall, there was a significant non-linear relationship over the range of flows studied (LR chi-square [2 degrees of freedom] = 31.8, p < 0.0001). Conclusions Adenosine-augmented MDCT myocardial perfusion imaging provides semiquantitative measurements of myocardial perfusion during first-pass MDCT imaging in a canine model of LAD stenosis.
Keywords :
MPI , coronary artery disease , LAD , CAD , SD , LV , left ventricle/ventricular , myocardial perfusion imaging , MBF , myocardial blood flow , left anterior descending artery , EBCT , electron beam computed tomography , MDCT , multidetector computed tomography , MBV , myocardial blood volume , signal density
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2006
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
471862
Link To Document :
بازگشت