Title of article :
Effects of Two Different Catheter Ablation Techniques on Spectral Characteristics of Atrial Fibrillation Original Research Article
Author/Authors :
Kristina Lemola، نويسنده , , Michael Ting، نويسنده , , Priya Gupta، نويسنده , , Jeffrey N. Anker، نويسنده , , Aman Chugh، نويسنده , , Eric Good، نويسنده , , Scott Reich، نويسنده , , David Tschopp، نويسنده , , Petar Igic، نويسنده , , Darryl Elmouchi، نويسنده , , Krit Jongnarangsin، نويسنده , , Frank Bogun، نويسنده , , Frank Pelosi Jr، نويسنده , , Fred Morady، نويسنده , , Hakan Oral، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
Objectives
The aim of this study was to determine the effects of circumferential pulmonary vein ablation (CPVA) and electrogram-guided ablation (EGA) on the spectral characteristics of atrial fibrillation (AF) and the relationship between changes in dominant frequency (DF) and clinical outcome.
Background
Circumferential pulmonary vein ablation and EGA have been used to eliminate AF. Spectral analysis may identify high-frequency sources.
Methods
In 84 consecutive patients, CPVA (n = 42) or EGA (n = 42) was performed for paroxysmal (n = 49) or persistent (n = 35) AF. During EGA, complex electrograms were targeted. Lead V1 and electrograms from the left atrium and coronary sinus were analyzed to determine the DF of AF before and after ablation.
Results
The left atrial DF was higher in persistent (5.83 ± 0.86 Hz) than paroxysmal AF (5.33 ± 0.76 Hz, p = 0.03). There was a frequency gradient from the left atrium to the coronary sinus (p = 0.02). Circumferential pulmonary vein ablation and EGA resulted in a similar decrease in DF (18 ± 17% vs. 17 ± 15%, p = 0.8). During a mean follow-up of 9 ± 6 months, the change in DF after CPVA was similar among patients with and without recurrent AF. An acute decrease in DF after EGA was associated with freedom from recurrent AF only in patients with persistent AF (19 ± 14% vs. 3 ± 6%, p = 0.02).
Conclusions
Both CPVA and EGA decrease the DF of AF, consistent with elimination of high-frequency sources. Whereas the efficacy of EGA is associated with a decrease in DF in patients with persistent AF, the efficacy of CPVA is independent of changes in DF. This suggests that CPVA and EGA eliminate different mechanisms in the genesis of persistent AF.
Keywords :
fast Fourier Transformation , FFT , Atrial fibrillation , dominant frequency , EGA , AF , CPVA , circumferential pulmonary vein ablation , DF , electrogram-guided ablation
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)