Title of article :
Abnormal Conduction Increases Risk of Adverse Outcomes From Right Ventricular Pacing Original Research Article
Author/Authors :
John J. Hayes، نويسنده , , Arjun D. Sharma، نويسنده , , John C. Love، نويسنده , , John M. Herre، نويسنده , , Anna O. Leonen، نويسنده , , Peter J. Kudenchuk and DAVID Investigators، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
1628
To page :
1633
Abstract :
Objectives The purpose of this study was to determine whether QRS duration or morphology increased the risk of adverse outcome in the DAVID (Dual Chamber and VVI Implantable Defibrillator) trial. Background The DAVID trial found an increased risk of the combined end point of death and new or worsening congestive heart failure (CHF) in defibrillator recipients who were paced DDDR-70 versus VVI-40. Methods We analyzed the combined end point in patients with abnormal QRS duration (AbQRS) (≥110 ms) compared with those with normal QRS duration (NQRS) (<110 ms). Results The QRS data were available for 496 of the 506 patients enrolled in the trial, including 223 patients with NQRS (45%) and 273 patients with AbQRS (55%). In patients in whom defibrillators were programmed to pace infrequently (VVI-40), having an NQRS or AbQRS was not an indicator of increased risk of adverse outcome. However, among patients in whom defibrillators were programmed in a manner that promoted more frequent ventricular pacing (DDDR-70), there was a significant adverse interaction with AbQRS; this combination was independently associated with a higher risk for developing CHF or death (p = 0.017). Conclusions Although patients with AbQRS tended to have other risk factors associated with poor outcome, the interaction of QRS duration with ventricular pacing (DDDR-70) independently contributed to a worse outcome and therefore, was a marker of patients in whom such treatment may be harmful. This should not imply that right ventricular pacing in NQRS patients is safe but rather that pacing in the context of an AbQRS is probably best avoided.
Keywords :
ICD , Congestive heart failure , CHF , LBBB , left bundle branch block , RBBB , right bundle branch block , implantable cardioverter-defibrillator , MOST , Mode Selection Trial , DAVID , AbQRS , abnormal QRS , Dual Chamber and VVI Implantable Defibrillator , IVCD , intraventricular conduction delay , NQRS , normal QRS
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2006
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
472098
Link To Document :
بازگشت