Title of article :
Non-Invasive Assessment of Endothelial Function: Which Technique? Original Research Article
Author/Authors :
Ann E. Donald، نويسنده , , Marietta Charakida، نويسنده , , Tim J. Cole، نويسنده , , Peter Friberg، نويسنده , , Phil J. Chowienczyk، نويسنده , , Sandrine C. Millasseau، نويسنده , , John E. Deanfield، نويسنده , , Julian P. Halcox، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
5
From page :
1846
To page :
1850
Abstract :
Objectives The purpose of this study was to compare 3 non-invasive techniques for assessment of endothelial function in adults and children and evaluate their utility in acute inflammation. Background Endothelial dysfunction is a key early event in pre-clinical atherosclerosis. Flow-mediated dilation (FMD), although the established technique, is expensive and technically demanding. Measurements of vascular responses to inhaled salbutamol by pulse wave analysis (PWA) or pulse contour analysis (PCA) are potential alternatives. Methods Sixteen adults (mean age 28 years, range 18 to 39) and 16 children (mean age 13 years, range 7 to 17) underwent concurrent vascular function testing on 2 occasions with ultrasound, PWA, and PCA. Eighteen men were also studied before and after typhoid vaccination. Results Reproducibility of FMD was high in adults and children (coefficient of variation [CV] = 7.1 and 6.3, respectively). Salbutamol responses were more variable with PWA (adults CV = 11.5, children CV = 17.1) and PCA particularly in children (adults CV = 18.2, children CV = 36.3). Flow-mediated dilation (p < 0.001) and PWA with salbutamol (p = 0.03) responses fell after typhoid vaccination, and PCA (p = 0.7) was unchanged. Conclusions Vascular dysfunction during acute inflammation can be measured by FMD and by PWA with salbutamol. Flow-mediated dilation is less variable than PWA. Variability of PCA makes this technique currently unsuited to serial measures of endothelial function in children. Flow-mediated dilation remains the most reproducible method.
Keywords :
d , nitric oxide , PCA , DP , NO , Diameter , PAI , Ri , FMD , flow-mediated dilation , GTN , glyceryl trinitrate , reflection index , DB , baseline diameter , peak diameter , peripheral augmentation index , ?PAIG , maximal change in PAI after GTN administration , ?PAIS , maximal change in PAI after salbutamol administration , pulse contour analysis , PWA , pulse wave analysis , ?RIG , maximal change in RI after GTN administration , ?RIS , maximal change in RI after salbutamol administration
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2006
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
472141
Link To Document :
بازگشت