Title of article :
Effects of Oral Prednisone After Stenting in a Rabbit Model of Established Atherosclerosis Original Research Article
Author/Authors :
Flavio Ribichini، نويسنده , , Michael Joner، نويسنده , , Valeria Ferrero، نويسنده , , Aloke V. Finn، نويسنده , , Johanna Crimins، نويسنده , , Gaku Nakazawa، نويسنده , , Eduardo Acampado، نويسنده , , Frank D. Kolodgie، نويسنده , , Corrado Vassanelli، نويسنده , , Renu Virmani، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
10
From page :
176
To page :
185
Abstract :
Objectives The aim of this study was to compare the effects of systemic prednisone in combination with a bare-metal stent (BMS) or a paclitaxel-eluting stent (Taxus, Boston Scientific Corp., Natick, Massachusetts) on neointimal inhibition and vessel healing in an atherosclerotic rabbit model. Background Inflammation plays a critical role in neointimal formation after coronary artery stenting. The efficacy of immunosuppressive doses of oral prednisone to inhibit in-stent neointimal proliferation was compared with BMS and with a commercially available paclitaxel-eluting stent (Taxus) in a rabbit model of established atherosclerosis. Methods Bilateral iliac artery injury in atherosclerotic New Zealand White rabbits fed an atherogenic diet was followed by stent implantation. Animals randomly received Taxus stents, BMS (Express, Boston Scientific Corp.) and placebo, or BMS and oral prednisone (2.1 mg/kg/day for the first 7 days, followed by 1.4 mg/kg/day for 14 days and 0.7 mg/kg/day for 21 days). Stented arterial segments were harvested at 42 days and processed for light microscopy, immunohistochemistry, and organoid culture. Results Compared with control subjects, prednisone-treated animals showed a 30% reduction in percent stenosis (p = 0.009), a 35% decrease in neointimal area (p < 0.003), and a 66% decrement in neointimal thickness (p < 0.001). Taxus stents also reduced all 3 parameters significantly (−34%, −39%, and −83%, respectively), but showed significantly more inflammatory cells and fibrin deposition and less endothelialization compared with the other 2 groups. Plaque burden was equal among groups, as shown by the identical stent and vessel area, and no remodeling was observed. Conclusions Systemic prednisone treatment and Taxus stents reduce neointimal formation compared with BMS. The extent of neointimal reduction is similar between prednisone- and Taxus stent-treated animals; however, Taxus stents resulted in a significantly greater delay in healing. Targeting of inflammatory pathways after percutaneous coronary intervention may be an efficacious way to prevent restenosis without the long-term risk of late thrombosis.
Keywords :
BSA , BMS , bovine serum albumin , C-reactive protein , DES , CRP , Drug-eluting stent , LSM , DMEM , bare-metal stent , Dulbecco’s modified Eagle’s medium , low-serum media
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2007
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
472652
Link To Document :
بازگشت