• Title of article

    Functional Characterization of Atrial Electrograms in Sinus Rhythm Delineates Sites of Parasympathetic Innervation in Patients With Paroxysmal Atrial Fibrillation Original Research Article

  • Author/Authors

    Nicolas Lellouche، نويسنده , , Eric Buch، نويسنده , , Andrew Celigoj، نويسنده , , Carin Siegerman، نويسنده , , David Cesario، نويسنده , , Carlos De Diego، نويسنده , , Aman Mahajan، نويسنده , , Noel G. Boyle، نويسنده , , Isaac Wiener، نويسنده , , Alan Garfinkel، نويسنده , , Kalyanam Shivkumar، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    8
  • From page
    1324
  • To page
    1331
  • Abstract
    Objectives This study sought to characterize left atrial (LA) sinus rhythm electrogram (EGM) patterns and their relationship to parasympathetic responses during atrial fibrillation (AF) ablation. Background The mechanistic basis of fractionated LA EGMs in patients with paroxysmal AF is not well understood. Methods We analyzed 1,662 LA ablation sites from 30 patients who underwent catheter ablation for paroxysmal AF. Pre-ablation EGM characteristics (number of deflections, amplitude, and duration) were measured in sinus rhythm. Parasympathetic responses during radiofrequency application (increase of atrial-His interval by ≥10 ms or decrease of sinus rate by ≥20%) were assessed at all sites. We also prospectively studied the effect of adenosine, a pharmacological agent mimicking acetylcholine signaling in myocytes, on LA EGMs. Finally, we performed mathematical simulations of atrial tissue to delineate possible mechanisms of fractionated EGMs in sinus rhythm. Results A specific pattern of pre-ablation sinus rhythm EGM (deflections ≥4, amplitude ≥0.7 mV, and duration ≥40 ms) was strongly associated with parasympathetic responses (sensitivity 72%, specificity 91%). The sites associated with these responses were found to be located mainly in the posterior wall of the LA. Adenosine administration and mathematical simulation of the effect of acetylcholine were able to reproduce a similar EGM pattern. Conclusions Parasympathetic activation during AF ablation is associated with the presence of pre-ablation high-amplitude fractionated EGMs in sinus rhythm. Local acetylcholine release could potentially explain this phenomenon.
  • Keywords
    EGM , Atrial fibrillation , radiofrequency , CART , Classification and regression tree , LA , RA , PV , RF , electrogram , AF , left atrial/atrium , right atrial/atrium , pulmonary vein , A–H , atrial-His , CFAE , complex fractionated atrial electrogram , HAFE , high-amplitude fractionated electrogram , LAFE , low-amplitude fractionated electrogram
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2007
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    472818