Title of article :
Influence of Heart Rate on the Diagnostic Accuracy of Dual-Source Computed Tomography Coronary Angiography Original Research Article
Author/Authors :
Ulrike Ropers، نويسنده , , Dieter Ropers، نويسنده , , Tobias Pflederer، نويسنده , , Katharina Anders، نويسنده , , Axel Kuettner، نويسنده , , Nikolaos I. Stilianakis، نويسنده , , Sei Komatsu، نويسنده , , Willi Kalender، نويسنده , , Werner Bautz، نويسنده , , Werner G. Daniel، نويسنده , , Stephan Achenbach، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
6
From page :
2393
To page :
2398
Abstract :
Objectives We evaluated the influence of heart rate on image quality and diagnostic accuracy of dual-source computed tomography (DSCT) coronary angiography. Background Multidetector computed tomography (MDCT) coronary angiography has demonstrated an inverse relationship between heart rate and image quality. Dual-source CT provides a higher temporal resolution. Methods One hundred patients were studied by DSCT (DEFINITION, Siemens Medical Solutions, Forchheim, Germany). A contrast-enhanced volume dataset was acquired (two tubes, 120 kV, 400 mAs/rot, collimation 64 × 0.6 mm). Datasets were evaluated concerning the presence of significant coronary stenoses and validated against invasive coronary angiography. Results In 44 patients with a heart rate ≥65 beats/min, 566 of 616 coronary segments were evaluable (92%), whereas in 56 patients with a heart rate <65 beats/min, 777 of 778 coronary segments were evaluable (100%, p < 0.001). On a per-patient basis, 93% of patients (≥65 beats/min) and 100% of patients (<65 beats/min) were considered evaluable. By classifying unevaluable segments as positive for stenosis, per-patient sensitivity was 95% (19 of 20) for heart rates ≥65 beats/min and 100% (22 of 22) for heart rates <65 beats/min. Specificity was 87% (21 of 24) versus 76% (26 of 34), and overall diagnostic accuracy was 91% (40 of 44) versus 86% (48 of 56). None of these differences were statistically significant. Similarly, no difference in diagnostic accuracy was found in per-vessel and -segment analyses. Conclusions In 100 patients studied without beta-blocker pre-medication, DSCT demonstrated slightly lower per-segment evaluability for high heart rates but no decrease in diagnostic accuracy for the detection of coronary artery stenoses.
Keywords :
CT , computed tomography , ECG , Electrocardiogram , MDCT , multidetector computed tomography , DSCT , dual-source computed tomography
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2007
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
472993
Link To Document :
بازگشت