Title of article :
No Benefit From Defibrillation Threshold Testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) Original Research Article
Author/Authors :
Joseph A. Blatt، نويسنده , , Jeanne E. Poole، نويسنده , , George W. Johnson، نويسنده , , David J. Callans، نويسنده , , Merritt H. Raitt، نويسنده , , Ramakota K. Reddy، نويسنده , , Francis E. Marchlinski، نويسنده , , Raymond Yee، نويسنده , , Thomas Guarnieri، نويسنده , , Mario Talajic، نويسنده , , David J. Wilber، نويسنده , , Jill Anderson، نويسنده , , Kiyon Chung، نويسنده , , Wai Shun Wong، نويسنده , , Daniel B. Mark، نويسنده , , Kerry L. Lee، نويسنده , , Gust H. Bardy and SCD-HeFT Investigators، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
6
From page :
551
To page :
556
Abstract :
Objectives This study investigated whether defibrillation threshold (DFT) testing during implantable cardioverter-defibrillator (ICD) implantation predicts clinical outcomes. Background Defibrillation testing is often performed during insertion of ICDs to confirm shock efficacy. There are no prospective data to suggest that this procedure improves outcomes when modern ICDs are implanted for primary prevention of sudden death. Methods The analysis included the 811 patients who were randomized to the ICD arm of the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) and had the device implanted. The DFT testing protocol in SCD-HeFT was designed to limit shock testing in a primary prevention heart failure population. Results Baseline DFT data were available for 717 patients (88.4%). All 717 patients had a DFT of ≤30 J, the maximum output of the device in this study. The DFT was ≤20 J in 97.8% of patients. There was no survival difference between patients with a lower DFT (≤10 J, n = 547) and a higher DFT (>10 J, n = 170) (p = 0.41). First shock efficacy was 83.0% for the first clinical ventricular tachyarrhythmia event; there were no differences in shock efficacies when the cohort was subdivided by baseline DFT. Conclusions Low baseline DFTs were obtained in patients with stable, optimally treated heart failure during ICD implantation for primary prevention of sudden death. First shock efficacy for ventricular tachyarrhythmias was high regardless of baseline DFT testing results. Baseline DFT testing did not predict long-term mortality or shock efficacy in this study.
Keywords :
sudden cardiac death , implantable cardioverter-defibrillator , defibrillation threshold testing , DFT testing
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2008
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
473498
Link To Document :
بازگشت