Title of article :
T wave normalization in infarct-related electrocardiographic leads during exercise testing for detection of residual viability: comparison with positron emission tomography
Author/Authors :
Gianni Mobilia، نويسنده , , Pierluigi Zanco، نويسنده , , Mariacristina Iovino and Alessandro Desideri، نويسنده , , Gianfilippo Neri، نويسنده , , Ferdinando Alitto، نويسنده , , Gianleone Suzzi، نويسنده , , Franc Chierichetti، نويسنده , , Leopoldo Celegon، نويسنده , , Giorgio Ferlin، نويسنده , , Riccardo Buchberger، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Abstract :
Objectives. We investigated the sensitivity and specificity of exercise-induced T wave normalization (TWN) in infarct-related electrocardiographic leads (IRLs) for detection of residual viability in the infarct area.
Background. The meaning of exercise-induced TWN on IRLs is not yet well understood. Recent reports suggest that TWN during dobutamine echocardiography could indicate the presence of viable myocardium.
Methods. We evaluated 40 consecutive patients with recent acute myocardial infarction and negative T waves in at least two IRLs. All patients underwent exercise testing; positron emission tomography (PET) with nitrogen-13 ammoni and fluorine-18 fluorodeoxyglucose; and coronary angiography.
Results. Twenty-four patients showed exercise-induced TWN: 18 at work load ≤50 W (group 1a) and 6 at work load ≥75 W (group 1b); 16 patients did not show TWN (group 2). On the PET study, viability in the infarct are was present in 17 patients (94%) from group 1a, in only 1 (16%) from group 1b and in 4 (25%) from group 2 (p < 0.0001). The sensitivity, specificity and diagnostic accuracy of exercise-induced TWN, in comparison with residual viability, were, respectively, 82%, 67%, 75% for TWN at every work load and 77%, 94%, 85% for TWN at work load ≤50 W. Moreover, the sensitivity and diagnostic accuracy of TWN at the low work load were higher for anterior infarctions (87% and 88%, respectively).
Conclusions. Exercise-induced TWN on IRLs at low work loads is sensitive and specific index for the presence of residual viability in the infarct area. Sensitivity and diagnostic accuracy of this sign are higher for anterior infarctions.
Keywords :
PET , ECG , IRLS , Electrocardiogram , electrocardiographic , fluorine-18 fluorodeoxyglucose , N-13 , nitrogen-13 , positron emission tomography (tomographic) , F-18 FDG , infarct-related ECG leads , TWN , T wave normalization
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)