Title of article :
Reliability of quantitative and qualitative tests to identify heterozygotes carrying severe or mild G6PD deficiency
Author/Authors :
Antonio Tagarelli، نويسنده , , Anna Piro، نويسنده , , Loredana Bastone، نويسنده , , Francesca Condino، نويسنده , , Giuseppe Tagarelli، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
4
From page :
183
To page :
186
Abstract :
Objectives: To determine if the qualitative test (cytochemical) is more reliable than the quantitative test (differential pH-metry) in identifying heterozygous G6PD− subjects. Design and methods: Identification of heterozygous G6PD− subjects was done by the measurement of G6PD activity and by a cytochemical test. Results: A cytochemical test is more sensitive than differential pH-metry to identify heterozygous G6PD− subjects. Conclusions: A cytochemical test is a reliable method for mass screening for G6PD deficiency to identify G6PD− heterozygotes.
Keywords :
southern Italy , G6PD deficiency , Differential pH-metry , Cytochemical test , Calabria population
Journal title :
Clinical Biochemistry
Serial Year :
2006
Journal title :
Clinical Biochemistry
Record number :
484703
Link To Document :
بازگشت