Title of article :
Biomechanical rationale of ossification of the secondary ossification center on apophyseal bony ring fracture: A biomechanical study
Author/Authors :
Ahmad Faizan، نويسنده , , Koichi Sairyo، نويسنده , , Vijay K. Goel، نويسنده , , Ashok Biyani، نويسنده , , Nabil Ebraheim، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
5
From page :
1063
To page :
1067
Abstract :
Background Apophyseal ring fracture is one of the important pathologies causing low back pain in children and adolescents. Most of the patients are reported to be in the ossification stage of the ring during growth period rather than early cartilaginous ring stage. There is no previous study clarifying the mechanism of the high prevalence of this disorder in the ossification stage. Thus, in this study, we investigated the effects of ossification of the ring on lumbar spine biomechanics. Methods Two three-dimensional finite element pediatric lumbar models were created and analyzed. One model had ossified apophyseal rings and the other one had cartilaginous apophyseal rings. To simulate standing posture, 341 N axial compression was applied. Then, 10 N m moment was applied to the model in the six directions of lumbar motion: flexion, extension, lateral bending and axial rotation. Maximum Von Mises stresses in the apophyseal ring were calculated and compared between the two models. Findings The maximum stresses were always higher in the bony ring in all lumbar motion at all lumbar levels compared to the cartilaginous ring. The stresses at L4 caudal apophyseal ring in extension were 2.60 and 0.68 (MPa) for bony and cartilaginous rings respectively. In flexion, stresses were 3.95 and 1.49 (MPa), in lateral bending, stresses were 6.75 and 2.66 (MPa), and in axial rotation, stresses were reported to be 3.15 and 1.72 (MPa). Thus, the bony ring was stressed by at least 2-fold more than the cartilaginous ring. Interpretation Apophyseal ring has at least two times more stresses in the ossified stage when compared to the cartilaginous stage resulting in frequent fractures at the interface of bone and cartilage.
Keywords :
Apophyseal ring , Lumbar spine , biomechanics , Pediatric , Finite element
Journal title :
Clinical Biomechanics
Serial Year :
2007
Journal title :
Clinical Biomechanics
Record number :
486792
Link To Document :
بازگشت