Title of article :
Comparison of the performance of 3D camera systems II
Author/Authors :
Yoshihiro Ehara، نويسنده , , Hiroshi Fujimoto and Yoichi Hori، نويسنده , , Shinji Miyazaki، نويسنده , , Masaaki Mochimaru، نويسنده , , Shigeru Tanaka، نويسنده , , Sumiko Yamamoto، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
5
From page :
251
To page :
255
Abstract :
The accuracy and processing time of 11 commercially available 3D camera systems were tested to evaluate their performance in clinical gait evaluation. The systems tested were Ariel APAS, Dynas 3D/h, Elite Plus, ExpertVision, PEAK5, PRIMAS, Quick MAG, VICON 140, VICON 370, color Video Locus and reflective Video Locus. The 3D locations of markers on both ends of a rigid bar were determined. The distance between these markers was calculated from these data and compared with the true value, which was measured with a slide caliper prior to the measurement. For the estimation of noise, 3D coordinates of the markers were measured while the same rigid bar was placed on the floor, and the standard deviations were calculated. The processing time for calculating 3D coordinates from data obtained during normal gait was measured.
Keywords :
3D camera systems , COMPARISON , Standardized condition , gait measurements
Journal title :
Gait and Posture
Serial Year :
1997