Title of article :
Detecting spinal posture change in sitting positions with tri-axial accelerometers
Author/Authors :
Wai Yin Wong، نويسنده , , Man Sang Wong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
A method of using three tri-axial accelerometers for monitoring postural changes in sitting was introduced. Subjects were requested to perform forward trunk flexion and lateral bending. A motion analysis system and a three-dimensional rotation alignment device were used to verify the measurements of the accelerometers.
The precision and reliability of the accelerometers for measuring static calibration was demonstrated as ≤1° for the RMS error and 1.000 for ICC(3,1). For measurements of sitting posture, the averaged RMS difference between the measurements of the accelerometers and the motion analysis system were ≤5° for all sitting postures on the coronal and sagittal planes. The results of this study demonstrated that tri-axial accelerometers could be used for tracking spinal postural changes on the sagittal and coronal planes in the sitting positions.
Keywords :
Spinal posture , Accelerometer , Sitting , Motion analysis system , Posture monitoring
Journal title :
Gait and Posture
Journal title :
Gait and Posture