Title of article :
Antimony speciation at ultra trace levels using hydride generation atomic fluorescence spectrometry and 8hydroxyquinoline as an efficient masking agent
Author/Authors :
Deng، Tian-Long نويسنده , , Chen، Yu-Wei نويسنده , , Belzile، Nelson نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
-292
From page :
293
To page :
0
Abstract :
Depending on the pH of the matrix and the concentration of Sb(V), we observed that the atomic fluorescence emission due to Sb(V) could contribute up to 40% of the emission signal during the determination of Sb(III). This can cause significant errors in Sb speciation analyses. Besides, interferences from heavy metals such as Mn(II), Cu(II), Fe(III), Co(II) and Ni(II) can cause severe depression of the signals as compared to the insignificant effects caused by Zn(II), Fe(II), Sn(II) and Pb(II). The compound 8-hydroxyquinoline was found to be an efficient agent to eliminate interference of transition metals in the determination of Sb by hydride generation-atomic fluorescence spectroscopy (HG-AFS). In addition, 8hydroxyquinoline can effectively mask undesired fluorescence emission from Sb(V) during the determination of Sb(III) and make Sb speciation more accurate. The presence of 8hydroxyquinoline does not modify the oxidation state of Sb in the sample and the possible metal complexes formed with 8-hydroxyquinoline were stable for more than 8h. When Lcysteine was introduced as a pre-reductant, a high background signal was observed and it proved to be inefficient as a reductant when the concentrations of Sb(III) were low. A sensitive and interference-free procedure was then developed for the speciation of lake water samples and for the determination of Sb in sediments.
Keywords :
Butadiene , electronic nose , Headspace , mercury , formaldehyde , Polymers
Journal title :
Analytica Chimica Acta
Serial Year :
2001
Journal title :
Analytica Chimica Acta
Record number :
49253
Link To Document :
بازگشت