Title of article
Shear modulus—Measurement methodology with application to light-cured resin composites
Author/Authors
Tamar Brosh، نويسنده , , Raphael Pilo، نويسنده , , Mircea Arcan، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
6
From page
52
To page
57
Abstract
Objectives. This study was conducted to test a novel methodology for shear modulus determination of light-cured resin composites.
Methods. Using a butterfly-shaped specimen, a special loading device was able to apply pure uniform shear stress on a significant region of the specimen. Validation of the method was proven by photoelastic experiments. Shear modulus was directly obtained through shear stress-strain curve where the strains were measured by a shear strain gauge rosette. The composite materials analyzed were one microfill (Silux Plus, 3M Dental Products) and four hybrids (Brilliant, Coltene; Herculite XRV, Kerr; Z-100, 3M Dental Products; Graft LC, GC). Analysis of variance was used to evaluate the G modulus (P<0.01).
Results. Modulus values varied between 2.54–8.01 GPa. The microfilled material presented the lowest value, and Graft LC presented the highest value. A statistically significant difference was found between all materials (p<0.01).
Significance. The described methodology can also be applied to other restorative materials, as well as to adhesion strength measurements.
Journal title
Dental Materials
Serial Year
1996
Journal title
Dental Materials
Record number
505228
Link To Document