Title of article :
Corrosion susceptibility of titanium covered by dental cements
Author/Authors :
Y.L Turpin، نويسنده , , R.D Tardivel، نويسنده , , A Tallec، نويسنده , , A.C Le Menn، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
5
From page :
57
To page :
61
Abstract :
Objectives: The aim of this study is to determine the influence of acidic fluorinated cements (as glass ionomer (GI) cements) on the passivation of titanium, using electrochemical investigations. Methods: We realized experimental electrodes that associate titanium and dental cements. Polarization resistance of titanium electrodes has been determined for uncovered metal and electrodes covered with three dental cements. Studentʹs t-tests proved the reproducibility. We also compared successive voltammograms for uncovered titanium and GI covered titanium. Results: Correct passivation was observed with zinc eugenate, but fluorinated GI or zinc phosphate coverage increased the corrosion susceptibility. Significance: However there is no evidence of titanium depassivation when covered with cement. No clinical contraindication can be held.
Keywords :
Dental cements , Polarization resistance , Titanium electrode
Journal title :
Dental Materials
Serial Year :
2000
Journal title :
Dental Materials
Record number :
505459