Title of article :
Indentation modulus and hardness of whisker-reinforced heat-cured dental resin composites
Author/Authors :
H. H. K. Xu، نويسنده , , D. T. Smith، نويسنده , , G. E. Schumacher، نويسنده , , F. C. Eichmiller، نويسنده , , J. M. Antonucci، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
7
From page :
248
To page :
254
Abstract :
Objectives: Recent studies showed that ceramic whisker reinforcement imparted a two-fold increase in the strength of dental composites. The aim of this study was to investigate the indentation response and measure the elastic modulus, hardness, and brittleness of whisker-reinforced heat-cured resin composites as a function of filler level, heat-cure temperature, and heat-cure duration. Methods: Silica particles were fused onto silicon nitride whiskers to facilitate silanization and to roughen the whiskers for improved retention in matrix. Whisker filler mass fractions of 0, 20, 40, 60, 70, 74 and 79% were tested. Heat-cure temperature ranged from 100 to 180°C, and duration from 10 min to 24 h. A nano-indentation system enabled the measurement of elastic modulus. Fracture toughness was measured and composite brittleness index was calculated. An inlay/onlay composite and a prosthetic composite were tested as controls. Results: Whisker filler level and heat-cure duration had significant effects on composite properties, while heat-cure temperature had non-significant effects. The whisker composite with 79% filler level had a modulus in GPa (mean (SD); n=6) of 26.9 (1.0), significantly higher than 15.1 (0.2) of an inlay/onlay control, and 16.1 (0.3) of a prosthetic control (Tukeyʹs multiple comparison test; family confidence coefficient=0.95). The fracture toughness in MPa·m1/2 was 2.22 (0.26) for the whisker composite, higher than 0.95 (0.11) for inlay/onlay control, and (1.13±0.19) for prosthetic control. The brittleness index was (0.49±0.07) for whisker composite, lower than (1.02±0.12) for inlay/onlay control and (0.63±0.13) for prosthetic control. Significance: Whisker filler level had a profound influence, heat-cure duration had significant effects, while temperature did not have significant effects, on the properties of whisker composite. The whisker composite had significantly higher elastic modulus and fracture toughness, and lower brittleness than the inlay/onlay and prosthetic controls.
Keywords :
Ceramic whisker , Heat cure , Resin Composite , Indentation , Elastic modulus , Fracture toughness , brittleness , Filler level
Journal title :
Dental Materials
Serial Year :
2000
Journal title :
Dental Materials
Record number :
505486
Link To Document :
بازگشت