Title of article :
Reinforcement effect of adhesively luted fiber reinforced composite versus titanium posts
Author/Authors :
Michael Naumann، نويسنده , , Anja Preuss، نويسنده , , Roland Frankenberger، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
Objective
The aim of the present study was to investigate the influence of the rigidity of different post materials (titanium versus glass fiber reinforced composite [FRC]) on the fracture resistance of endodontically treated teeth (ETT).
Method
Forty-eight caries-free maxillary central incisors were randomly assigned to six groups (n = 8). After endodontic treatment, teeth of four groups were flattened 2 mm above and two groups at the cemento-enamel junction (CEJ). As control, specimens of one group received neither composite build-up nor post, and teeth were left empty (E). In another group only a resin composite build-up was placed (C). In two groups, both titanium and FRC posts were inserted. One group with titanium (2/T) and FRC (2/FRC) post received a 2 mm deep ferrule preparation. For one group with titanium (0/T) and FRC (0/FRC) post no ferrule design was provided. All-ceramic crowns were adhesively luted on all specimens. Specimens were exposed to thermomechanical loading and finally statically loaded until failure.
Results
The median fracture load values (min–max) were: E = 317 (242–404); C = 387 (335–475); 0/FRC = 352 (0–440); 2/FRC = 502 (326–561); 0/T = 420 (0–548), 2/T = 517 (416–653). Statistically significant differences were computed between E, C, 2/FRC, 0/T and 2/T; between C, 2/FRC and 2/T; between 0/FRC, 2/FRC and 2/T; between 0/T and 2/T regarding maximum fracture load.
Significance
Fracture resistance of ETT is not influenced by the rigidity of the post material. The combination of ferrule preparation and endodontic post results in higher load resistance after TML than any other build-up design.
Keywords :
Endodontic post , Fracture load , dowel , Ferrule
Journal title :
Dental Materials
Journal title :