Title of article :
Cuspal movement and microleakage in premolar teeth restored with resin-based filling materials cured using a ‘soft-start’ polymerisation protocol
Author/Authors :
G.J.P. Fleming، نويسنده , , R.R. Cara، نويسنده , , W.M. Palin، نويسنده , , F.J.T. Burke، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
7
From page :
637
To page :
643
Abstract :
Objectives To investigate the effect of polymerisation shrinkage strain of four posterior filling materials on cuspal movement, degree of conversion (DC) and cervical gingival microleakage of mesio-occlusal-distal (MOD) restorations placed incrementally in maxillary premolar teeth using a ‘soft-start’ polymerisation protocol. Methods Forty sound extracted upper premolar teeth were subjected to standardised preparation of a large MOD cavity before restoration. A ‘soft-start’ polymerisation curing regimen was used and each posterior filling material was placed in eight increments with the appropriate bonding system. A twin channel deflection measuring gauge allowed a measurement of individual cusp deflections at each stage of polymerisation. Restored teeth were thermocycled before immersion in a 0.2% basic fuchsin dye for 24 h. After sagittal sectioning of the restored teeth in a mesio-distal plane, the sectioned restorations were examined to assess cervical microleakage. The DC was also assessed using a diffuse-reflectance accessory on a Fourier transform infra-red spectrophotometer. Results A significant increase in cuspal movement recorded for Z100 (20.06 ± 4.71) compared with Filtek Z250™ (16.52 ± 3.26), P60 (14.23 ± 3.71) and Admira (11.11 ± 2.47). No significant reduction in cuspal movement was identified when compared with a previous study [6] where a full-intensity standard polymerisation protocol was employed. No significant differences were also identified between the materials when the cervical gingival microleakage scores or DC were examined for the ‘soft-start’ compared with the standard polymerisation protocol. Conclusions Although material type remained a significant factor, the use of a ‘soft-start’ polymerization compared with a standard curing regime did not offer any significant reduction in associated cuspal movement, DC or gingival microleakage at the cervical dentine cavosurface margin of the cavities restored with the resin-based filling materials.
Keywords :
Soft-start polymerisation , Resin-based composite , Cuspal movement , Gingival microleakage , ORMOCER
Journal title :
Dental Materials
Serial Year :
2007
Journal title :
Dental Materials
Record number :
506282
Link To Document :
بازگشت