Title of article :
Shrinkage stress in light-cured composite resins: Influence of material and photoactivation mode
Author/Authors :
Christophe Charton، نويسنده , , Pierre Colon، نويسنده , , Fernand Pla، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
10
From page :
911
To page :
920
Abstract :
Objectives The aim of this study was to record the effect of composite type and photoactivation mode on the stresses resulting from polymerization of five established composite resins: packable (Solitaire, Solitaire 2), micro-hybrid (Aelitefil, Z100) and hybrid (Clearfil AP-X). Methods A mechanical testing machine was used to record the polymerization contraction stress (MPa) of cylindrical composite specimens (d = 5 mm; h = 2 mm; C-factor = 1.25) at 0.1 s intervals over a period of 400 s. The samples were photopolymerized using a halogen light curing device under two types of light exposure: group 1, Standard (800 mW·cm−2 × 60 s); group 2, Exponential (logarithmic increase from 150 to 800 mW·cm−2 over 15 s + 800 mW·cm−2 × 45 s). The stress rate (SR: slopeMPa>0–60 s) and the maximum shrinkage stress (MSS: MPa400 s) of each material (five replications) were statistically analysed by one-way ANOVA/Scheffeʹs test and Pearsonʹs correlation procedure (α = 0.05). Finally, Studentʹs t-test (two matched series) enabled the assessment of the effect of the irradiation method on the results. Results For group 1, in decreasing order, the MSS was 1.51 ± 0.07 MPa (Solitaire) statistically equivalent to 1.45 ± 0.06 MPa (Aelitefil), 1.29 ± 0.08 MPa (Solitaire 2), and 1.04 ± 0.03 MPa (Z100) statistically equivalent to 0.92 ± 0.05 MPa (Clearfil AP-X). Z100 showed the highest SR (0.045 ± 6 × 10−3) and Solitaire, the lowest (0.017 ± 2 × 10−3). There was no correlation between SR and MSS (r < −0.33, p < 0.05). For group 2, the MSS and SR values were distributed in a similar way to those from group 1. There was a negative correlation between SR and MSS (r < −0.43 and p < 0.01). The exponential ramp successfully reduced the MSS (−3.9%) and SR (−11%) values. Significance There is no relationship between composite resin type, stress rate and shrinkage stress levels. The slower stress rate development, resulting from ramped light intensity, helped slightly to reduce the maximum polymerization stress.
Keywords :
Light-curing , Shrinkage stress , Composite resin , polymerization , viscous flow
Journal title :
Dental Materials
Serial Year :
2007
Journal title :
Dental Materials
Record number :
506319
Link To Document :
بازگشت