Application of DIAGNOdent® as a guide for removing carious dentin with Er:YAG laser
Author/Authors
Kazuaki Yonemoto، نويسنده , , Toru Eguro، نويسنده , , Toru Maeda، نويسنده , , Hisayoshi Tanaka، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
8
From page
269
To page
276
Abstract
Objectives
The purpose of this study was to investigate the DIAGNOdent® values applicable as a guide for removal of outer layer of carious dentin with Er:YAG laser.
Methods
Carious dentin of human extracted molars was removed by bur with Caries Detector® (Group 1: red stained dentin was left, Group 2: light pink stained dentin was left) and by Er:YAG laser with DIAGNOdent® value as a guide (30>Group 3>21, 20>Group 4>11, 10>Group 5). The cavity floor dentin after removing carious dentin was examined using microradiograms, EPMA and SEM.
Results
The cavity floor dentin of group 1,3 showed the decreases in the degree of X-ray absorption. In group 2,4 and 5, decrease of Ca, P were not observed. The decrease of Mg was observed on the more superficial part of the cavity floor for group 3 than for group 4.
Conclusions
When carious dentin was removed using Er:YAG laser, the carious dentin outer layer was ideally removed with DIAGNOdent® values: 11–20. DIAGNOdent® values: 11–20, could indicate the completion of outer layer removal of carious dentin with Er:YAG laser, but there are some problems that must be addressed before the clinical application.
Keywords
Microradiographicobservation , SEM observation , DIAGNOdentw , Er:YAG laser , Caries removal , Carious dentin , EPMA analysis , Guide of carious dentinremoval