Title of article :
Optimisation of the long-term efficacy of dental chair waterline disinfection by the identification and rectification of factors associated with waterline disinfection failure
Author/Authors :
M.J. O’Donnell، نويسنده , , A.C. Shore، نويسنده , , R.J. Russell، نويسنده , , D.C. Coleman، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
14
From page :
438
To page :
451
Abstract :
Although many studies have highlighted the problem of biofilm growth in dental chair unit waterlines (DUWs), no long-term studies on the efficacy of DUW disinfection using a large number of dental chair units (DCUs) have been reported. Objectives To investigate the long-term (21 months) efficacy of the Planmeca Waterline Cleaning System (WCS™) to maintain the quality of DUW output water below the American Dental Association (ADA) recommended standard of ≤200 cfu/mL of aerobic heterotrophic bacteria using once weekly disinfection with the hydrogen peroxide-and silver ion-containing disinfectant Planosil. Methods Microbiological quality of DUW output water was monitored by culture on R2A agar for 10 DCUs fitted with the WCS™. The presence of biofilm in DUWs was examined by electron microscopy. Results During the first 9 months a high prevalence (28/300 disinfection cycles; 9.3%) of intermittent DUW disinfection failure occurred in 8/10 DCUs due to operator omission to disinfect all DUWs (10/28 failed cycles), incorrect compressed air pressure failing to distribute the disinfectant properly (4/28 failed cycles) and physical blockage of disinfectant intake valves due to corrosion effects of Planosil (14/28 failed cycles). On rectification of these faults through engineering redesign and procedural changes, no further cases of intermittent DUW disinfection failure were observed. Independently of these factors, a rapid and consistent decline in efficacy of DUW disinfection occurred in 4/10 DCUs following the initial 9 months of once weekly disinfection. There was a highly significant difference (P < 0.0001) in the prevalence of strongly catalase-positive Novosphingobium and Sphingomonas bacterial species (mean average prevalence of 37.1%) in DUW output water from these 4 DCUs compared to the other 6 DCUs and DCU supply water (prevalence <1%), which correlated with biofilm presence in the DUWs and indicated selective pressure for maintenance of these species by prolonged disinfectant usage. Planosil was reformulated to a more concentrated form (Planosil Forte) and when used once weekly was found to maintain bacterial density in output water below the ADA standard for all 10 DCUs. Conclusions A variety of factors can contribute to failure of DUW disinfection in the long-term, including human error, disinfectant corrosion of equipment and natural selection of naturally disinfectant-tolerant bacterial species.
Keywords :
Dental chair waterlinesWaterline disinfectionWaterline biofilmCauses of waterline disinfectionfailureNovosphingobium speciesSphingomonas speciesCatalase-positive bacteriaNatural selection
Journal title :
Journal of Dentistry
Serial Year :
2007
Journal title :
Journal of Dentistry
Record number :
507635
Link To Document :
بازگشت