Temperature variation at the external root surface during 980-nm diode laser irradiation in the root canal
Author/Authors
E. Alfredo، نويسنده , , M.A. Marchesan، نويسنده , , M.D. Sousa-Neto، نويسنده , , A. Brugnera-J?nior، نويسنده , , Y.T.C. Silva-Sousa، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
6
From page
529
To page
534
Abstract
Objective
To assess the temperature variation in the cervical, middle and apical thirds of root external wall, caused by 980-nm diode laser irradiation with different parameters.
Methods
The roots of 90 canines, had their canals instrumented and were randomly distributed into 3 groups (n = 30) according to the laser potency (1.5 W, 3.0 W and 5.0 W). Each group was subdivided into 3 (n = 10) according to the frequency (CM, 100 Hz and 1000 Hz), and each subgroup divided into 2 (n = 5): dried canal or filled with distilled water. The maximum temperature values were collected by 3 thermocouples located at each third of the root external wall and recorded by digital thermometers.
Results
The groups irradiated in the continuous mode (CM) presented the highest values (11.82 ± 5.78), regardless of the canals were dry or not, which were statistically different (p < 0.01) from those obtained with 100 Hz (6.22 ± 3.64) and 1000 Hz (6.00 ± 3.36), which presented no statistical difference between them (p > 0.01). The groups irradiated with 5.0 W presented the greatest temperature variation (12.15 ± 5.14), followed by 3.0 W (7.88 ± 3.92) and 1.5 W (4.02 ± 2.16), differing between them (p < 0.01). The cervical third of the root presented the highest temperature rises (9.68 ± 5.80), followed by the middle (7.66 ± 4.87) and apical (6.70 ± 4.23), with statistical difference among them (p < 0.01). After 30 s from the end of irradiation, all the specimens presented temperature variation lower than 10 °C.
Conclusions
Application of 980-nm diode laser in the root, at 1.5 W in all operating modes, and 3.0 W, in the pulsed mode, for 20 s, can safely be used in endodontic treatment, irrespective of the presence of humidity.
Keywords
Diode laserTemperature increaseIntrapulpar irradiationEndodontics