Title of article :
Optimal scan delay of arterial phase scanning of hepatic CT using a real-time image reconstruction system
Author/Authors :
Tadafumi Shimizu، نويسنده , , Toshimasa Misaki، نويسنده , , Kazuhiro Yamamoto، نويسنده , , Yasunori Tanaka، نويسنده , , Keita Utsunomiya، نويسنده , , Kozo Sueyoshi، نويسنده , , Isamu Narabayashi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
4
From page :
107
To page :
110
Abstract :
To optimize scan delay of arterial phase scanning of hepatic CT, 30 patients suspected of having HCC were examined using real-time image reconstruction technology (SureStart). In all cases, SureStart was successful. Despite the low dose, these images allowed adequate visualization of the abdominal aorta. The mean delay from the initiation of contrast administration to the beginning of arterial phase scanning was 29.6 ± 5.2 sec (mean ± SD; range, 22–51 sec).
Keywords :
Liver , CT , contrast enhancement