• Title of article

    Amplification of Amperometric Biosensor Responses by Electrochemical Substrate Recycling. 3. Theoretical and Experimental Study of the Phenol-Polyphenol Oxidase System Immobilized in Laponite Hydrogels and Layer-by-Layer Self-Assembled Structures

  • Author/Authors

    Labbe، P. نويسنده , , Coche-Guerente، L. نويسنده , , Mengeaud، Virginie نويسنده ,

  • Issue Information
    دوهفته نامه با شماره پیاپی سال 2001
  • Pages
    -3205
  • From page
    3206
  • To page
    0
  • Abstract
    The amperometric response toward phenol of PPO-based rotating disk bioelectrodes is analyzed on the basis of a kinetic model taking into account internal and external mass transport effects and a CECʹ electroenzymatic mechanism. Monophenolase activity of PPO catalyses the oxidation of phenol to o-quinone (step C). o-Quinone can then enter an amplification recycling process involving electrochemical reduction (step E) and enzymatic reoxidation (step Cʹ: catecholase activity). The rate-limiting steps such as monophenolase activity, catecholase recycling, permeability of the membrane, and activity and accessibility of the catalytic enzyme sites are theoretically considered and experimentally demonstrated for different electrode configurations including PPO immobilized in Laponite hydrogels and layerby-layer self-assembled multilayers of PPO and poly(diallyldimethylammonium).
  • Journal title
    Analytical Chemistry
  • Serial Year
    2001
  • Journal title
    Analytical Chemistry
  • Record number

    50864