• Title of article

    Stereotactic breast biopsy of noncalcified lesions: A cost-minimization analysis comparing 14-gauge multipass automated core biopsy to 14- and 11-gauge vacuum-assisted biopsy

  • Author/Authors

    Mary Scott Soo، نويسنده , , Mark A. Kliewer، نويسنده , , Sujata Ghate، نويسنده , , Richard S. Helsper، نويسنده , , Eric L. Rosen، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    8
  • From page
    26
  • To page
    33
  • Abstract
    A decision model was used to compare the relative costs of the 14-gauge automated gun technique to the 14-gauge and 11-gauge vacuum-assisted techniques for stereotactic biopsy of noncalcified breast lesions. Probability and cost variables were estimated from clinical experience with 76 automated gun biopsies, seventy-eight 14-gauge vacuum-assisted biopsies and thirty-nine 11-gauge vacuum-assisted biopsies. The 14-gauge automated gun was the preferred strategy from a cost standpoint: the 14-gauge vacuum technique was 1.19 times more expensive, and the 11-gauge was 1.22 times more expensive.
  • Keywords
    breast neoplasms , diagnosis , Breast radiography , US , MR
  • Journal title
    Clinical Imaging
  • Serial Year
    2005
  • Journal title
    Clinical Imaging
  • Record number

    508794