Title of article :
The role of PET scan in the preoperative management of oesophageal cancer
Author/Authors :
G. Liberale، نويسنده , , J.L. Van Laethem، نويسنده , , F. Gay، نويسنده , , S. Goldman، نويسنده , , N. Nagy، نويسنده , , E. Coppens، نويسنده , , M. Gelin، نويسنده , , I.El. Nakadi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
Aim
The aim of this study was to evaluate the role of the 18F-FDG-PET in the preoperative evaluation of patients with oesophageal or gastro-oesophageal junction (GEJ) cancer and to define its impact on therapeutic management.
Patients and methods
This study included 58 patients with biopsy proven oesophageal or GEJ cancer who underwent PET in addition to the conventional diagnostic work-up. The sensitivity, specificity and accuracy of CT and PET were calculated for detection of tumour and distant metastases.
Results
The sensitivity, specificity and accuracy of tumour detection were, respectively, 84, 100 and 84% for CT and 87, 100 and 87% for PET (p=ns). PET permitted detection of distant metastases, which were not seen on CT in seven patients. In two patients, a second primary tumour was detected on PET.
Conclusions
The sensitivity of PET for loco regional lymph nodes detection is low. The major clinical impact is the detection of distant metastases.
Keywords :
18FDG-PET , oesophageal cancer , CT , EUS , accuracy , Staging
Journal title :
European Journal of Surgical Oncology
Journal title :
European Journal of Surgical Oncology