Title of article :
Sol-Gel Open Tubular ODS Columns with Reversed Electroosmotic Flow for Capillary Electrochromatography
Author/Authors :
Malik، Abdul نويسنده , , Hayes، James D. نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 2001
Pages :
-986
From page :
987
To page :
0
Abstract :
Sol-gel chemistry was successfully used for the fabrication of open tubular columns with surface-bonded octadecylsilane (ODS) stationary-phase coating for capillary electrochromatography (OT-CEC). Following column preparations, a series of experiments were performed to investigate the performance of the sol-gel coated ODS columns in OTCEC. The incorporation of N-octadecyldimethyl[3-(trimethoxysilyl)propyl]ammonium chloride as one of the sol-gel precursors played an important role in the electrochromatographic performance of the prepared columns. This chemical reagent possesses a chromatographically favorable, bonded ODS moiety, in conjunction with three methoxy groups allowing for sol-gel reactivity. In addition, a positively charged nitrogen atom is present in the molecular structure of this reagent and provides a positively charged capillary surface responsible for the reversed electroosmotic flow (EOF) in the columns during CEC operation. Comparative studies involving the EOF within such sol-gel ODS coated and uncoated capillaries were performed using acetonitrile and methanol as the organic modifiers in the mobile phase. The use of a deactivating reagent, phenyldimethylsilane, in the sol-gel solution was evaluated. Efficiency values of over 400 000 theoretical plates per meter were achieved in CEC on a 64 cm × 25 mu m i.d. sol-gel ODS open tubular column. Test mixtures of polycyclic aromatic hydrocarbons, benzene derivatives, and aromatic aldehydes and ketones were used to evaluate the CEC performances of both nondeactivated and deactivated open tubular sol-gel columns. The effects of mobile-phase organic modifier contents and pH on EOF in such columns were evaluated. The prepared sol-gel ODS columns are characterized by switchable electroosmotic flow. A pH value of ~8.5 was found correspond to the isoelectric point for the prepared sol-gel ODS coatings.
Keywords :
High-performance liquid chromatography-mass spectrometry (LC-MS) , Trifolium pratense , red clover , Isoflavone glycoside 6"-O-malonates , Isoflavone glycoside 6"-O-acetates , Solid-phase extraction (SPE)
Journal title :
Analytical Chemistry
Serial Year :
2001
Journal title :
Analytical Chemistry
Record number :
51799
Link To Document :
بازگشت