Title of article :
Comparison of rotational atherectomy with conventional balloon angioplasty in the prevention of restenosis of small coronary arteries: Results of the Dilatation vs Ablation Revascularization Trial Targeting Restenosis (DART)
Author/Authors :
Laura Mauri، نويسنده , , Mark Reisman، نويسنده , , Maurice Buchbinder، نويسنده , , Jeffrey J. Popma، نويسنده , , Samin K. Sharma، نويسنده , , Donald E. Cutlip، نويسنده , , Kalon K. L. Ho، نويسنده , , Ross Prpic، نويسنده , , Peter J. Zimetbaum، نويسنده , , Richard E. Kuntz، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
8
From page :
847
To page :
854
Abstract :
Background The optimum treatment of obstructive coronary disease in small (<3.0 mm diameter) arteries remains unknown. Rotational atherectomy is an approved treatment that might reduce the vascular injury during percutaneous coronary intervention compared with angioplasty. We report on a multicenter, randomized, blinded end point trial comparing rotational atherectomy with balloon angioplasty in the prevention of restenosis of obstructed small coronary arteries. Methods A total of 446 patients with myocardial ischemia associated with an angiographic stenosis in a native coronary artery 2 to 3 mm in diameter and ≤20 mm in length without severe calcification were randomly assigned to receive rotational atherectomy (n = 227) or balloon angioplasty (n = 219). The primary end point was target vessel failure at 12 months (defined as the composite of death, Q-wave myocardial infarction, and clinically driven repeat revascularization of the target vessel). Results The mean reference vessel diameter was 2.46 ± 0.40 mm, the mean lesion length was 9.97 ± 5.59 mm, and the prevalence of diabetes mellitus was 32%. Acute procedural success (91.6% for rotational atherectomy, 94.1% for balloon angioplasty, P = .36) and target vessel failure at 12 months were not significantly different (30.5% vs 31.2%, P = .98). At 8 months, there were no significant differences in minimum lumen diameter (1.28 ± 0.63 mm vs 1.19 ± 0.54 mm, P = .26), percent diameter stenosis (28% ± 12% vs 29% ± 15%, P = .59), binary restenosis rate (50.5% vs 50.5%, P = 1.0), or late loss index (0.57 vs 0.62, P = .7). No Q-wave myocardial infarctions occurred in either arm of the study, and non–Q-wave myocardial infarctions (defined as creatine kinase level >2 times normal with an elevated creatine kinase-myocardial band isoenzyme level) occurred in 2.2% and 1.4% of the patients in the rotational atherectomy and balloon angioplasty groups, respectively (P = .72). Conclusion Rotational atherectomy was found to be safe in the treatment of obstructed small arteries, but lower rates of target vessel failure were not achieved compared with balloon angioplasty. Because the acute gain and loss index ratios of the 2 treatments were similar, there was no evident beneficial antirestenosis mechanism seen for rotational atherectomy.
Journal title :
American Heart Journal
Serial Year :
2003
Journal title :
American Heart Journal
Record number :
533138
Link To Document :
بازگشت