Title of article :
An Internet-based registry examining the efficacy of heparin coating in patients undergoing coronary stent implantation
Author/Authors :
Roxana Mehran، نويسنده , , Eugenia Nikolsky، نويسنده , , Edoardo Camenzind، نويسنده , , Michael Zelizko، نويسنده , , Igor Kranjec، نويسنده , , Ricardo Seabra-Gomes، نويسنده , , Manuela Negoita، نويسنده , , Steven Slack، نويسنده , , Chaim Lotan MD FACC، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
6
From page :
1171
To page :
1176
Abstract :
Background Heparin coating is an attractive alternative to counterbalance intrinsic stent thrombogenicity and to decrease the incidence of stent thrombosis. Methods We compared, based on the data of an international multicenter prospective registry, the rates of stent thrombosis after percutaneous coronary interventions in native coronary arteries using a Bx VELOCITY heparin-coated stent versus a bare metal stent of the same design in a total of 3098 patients at high risk for stent thrombosis. Most patients in both groups underwent percutaneous coronary intervention for unstable angina (48.4% vs 47.5%, respectively) with >25% of the patients treated for acute myocardial infarction (30.8% and 28.1%, respectively). Results Procedural success was high and very similar in patients with heparin-coated and bare metal stents (99.3% vs 98.8%, respectively, P = .11). The primary end point, a 30-day stent thrombosis, occurred in 0.6% of the 1417 patients treated with the heparin-coated stent and 0.9% of the 1681 patients treated with the bare metal stent (relative risk reduction 33%, P = .41). The rates of cardiac death, myocardial infarction, and target lesion revascularization did not differ significantly between the groups. By multivariate analysis, variables independently associated with 30-day stent thrombosis included the evidence of thrombus at baseline (odds ratio [OR] 3.0, 95% CI 1.29-7.0, P = .01), small vessel stenting (OR 2.41, 95% CI 1.01-5.74, P = .05), and target left anterior descending artery (OR 2.32, 95% CI 1.00-5.38, P = .05). Conclusion This large-scale registry comparing the use of heparin-coated stent versus bare metal stent in the reality of daily practice showed no significant difference in stent thrombosis in patients with a high-risk profile for thrombotic complications.
Journal title :
American Heart Journal
Serial Year :
2005
Journal title :
American Heart Journal
Record number :
534197
Link To Document :
بازگشت