• Title of article

    Multielement photon activation analysis of a bulk lanthanum sample by a Ge-BGO Compton-suppression spectrometer

  • Author/Authors

    Y. Satoh، نويسنده , , K. Fukuda، نويسنده , , J. Ohkuma، نويسنده , , T. Asano and K. Kageyama، نويسنده , , R. Taniguchi، نويسنده , , M. Fujishiro، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1995
  • Pages
    4
  • From page
    999
  • To page
    1002
  • Abstract
    Photon activation analysis with a Ge-BGO Compton-suppression γ spectrometer has been studied for measuring the concentration of trace elements in a bulk lanthanum sample. Thirteen kinds of trace elements included in a test sample system have been analyzed, and the detection limit ranges from 9 × 10−2 to 1 × 10−3 μg/g, which corresponds to improvement by a factor of from 1.5 to 2.5 over that obtained by a conventional γ-ray spectrometer.
  • Journal title
    Applied Radiation and Isotopes
  • Serial Year
    1995
  • Journal title
    Applied Radiation and Isotopes
  • Record number

    539371