Title of article :
Irradiation and ESR analysis temperature dependence of the gamma-ray response of alanine-polystyrene dosimeters
Author/Authors :
T. Kojima، نويسنده , , N. Morishita، نويسنده , , H. Itoh، نويسنده , , S. Biramontri، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Abstract :
Response characteristics of the alanine-polystyrene dosimeter were studied at an absorbed dose of 5 kGy over the low irradiation temperature range −196 not, vert, similar 30°C, and the ESR analysis temperature range 0 not, vert, similar 50°C in the dose range 0.1 not, vert, similar 10 kGy. The irradiation temperature coefficient previously estimated for the temperature range from 0 not, vert, similar 70°C (+0.24%/°C) was verified down to −15°C, although about 8% lower values were obtained at −78 and −196°C based on the correction using the above coefficient. ESR intensity decreases with temperature during ESR analysis following the function of the reciprocal of absolute temperature based on Boltzmannʹs constant. The average temperature coefficient for three different dose levels during ESR analysis of the alanine-polystyrene dosimeter is −0.25%/K in the temperature range 0 not, vert, similar 50°C.