Title of article :
Alanine-polystyrene dosimeters prepared by injection moulding
Author/Authors :
T. Kojima، نويسنده , , S. Kashiwazaki، نويسنده , , Y. Zhang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Abstract :
The alanine-polystyrene dosimeters analysed by electron spin resonance (ESR) spectrometry were manufactured for large-scale use as a routine dosimeter in industrial radiation processing facilities by using an injection moulding method. Injection moulding enables us to achieve mass production of uniform dosimeters at a reduced cost. Their primary characteristics for dosimetry were studied in terms of their gamma-ray dose-response at radiation processing dose levels, precision, and effect of temperature during irradiation at an absorbed dose of 1 kGy. The precision of dose-response in the range 0.1–100 kGy is within ± 2% at a 68% confidence level with and without correction for sample-to-sample mass scattering. The irradiation temperature coefficient for dosimeters irradiated to 1 kGy is estimated to be 0.25%/°C, by normalizing to those irradiated at 25°C in the temperature range from 5 to 45°C. The fading of the radiation-induced ESR signal at doses of 0.1–100 kGy at 25°C and r.h. 40% is <1% for at least 2 months after irradiation.
Journal title :
Applied Radiation and Isotopes
Journal title :