Title of article :
Comparison between different types of glass and aluminum as containers for irradiation samples by neutron activation analysis
Author/Authors :
A. Sroor، نويسنده , , N. Walley El-Dine، نويسنده , , A. El-Shershaby، نويسنده , , A. S. Abdel-Haleem، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
5
From page :
147
To page :
151
Abstract :
Three different types of glass and four different kinds of aluminum sheet have been analyzed using neutron activation analysis. The irradiation facilities of the first Egyptian research reactor (ET-RR-1) and a hyper-pure germanium (HPGe) detection system were used for the analysis. Among the 34 identified elements, the isotopes 60Co, 65Zn, 110mAg, 123mTe, 134Cs, 152Eu and 182Ta are of special significance because of their long half-lives, providing a background interference for analyzed samples. A comparison between the different types of containers was made to select the preferred one for sample irradiation.
Journal title :
Applied Radiation and Isotopes
Serial Year :
2000
Journal title :
Applied Radiation and Isotopes
Record number :
540527
Link To Document :
بازگشت