Title of article :
Optimisation of cyclotron production parameters for the 209Bi(α, 2n) 211At reaction related to biomedical use of 211At
Author/Authors :
Gjermund Henriksen، نويسنده , , Svein Messelt، نويسنده , , Eivind Olsen، نويسنده , , Roy H. Larsen، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
6
From page :
839
To page :
844
Abstract :
The cyclotron alpha beam production of 211At and of the contaminant 210At related to beam energy were studied. Radiochemical purification of 211At from the other main contaminant, 210Po, by an extraction procedure was also evaluated. To avoid impurities 28 MeV has previously been considered as a maximum beam energy, but by using instead 29.1 MeV as a limit a large increase in EOB yield and sufficient radiochemical purity of extracted 211At were obtained. More cyclotrons could thereby deliver quantities useful for clinical cancer trials.
Keywords :
Beam optimisation , 211At , 210Po , Alpha emitters , Energy calibration , 210At